Liquid level in enameled vessels measured over the bottom valve
• bubbling-through measurement • differential pressure measurement • bottom valve
Measuring of liquid level in glass-lined vessels
over bottom valve
• bottom valve glass-lined/steel 150/100
• measuring gerinne tantalum
• special pipe coupling Hastelloy C 22
• bubbling-through measurement
• 100% filling height acquirement
• no things built in
• inlet pipe be abolished
• EX zone 0
picture
Measuring of liquid level in glass-lined agitating vessels
Advantages:
• entire filling height acquirement
• inlet pipe be abolished
• small costs
• equipment standard is preserved
No problem with an accordingly equipped glass-lined bottom valve. Why is this recommended?
By the standardization of the agitating vessels according to DIN 28 136 these only have one bottom nozzle. In
this the bottom valve is installed, over it is 100% filling height volume. The valve stem is equipped with a tantallum pipe, which has a special pipe coupling outlet. Through the bottom valve inert gas will be introduced and measured by differntial pressure transmitter against the gas space of the vessel head.
We supply the glass-lined bottom valve with tantallum measuring gerinne.
Measuring of liquid level over bottom valve acquires the entire filling height
• acid resistant • inherent safety • exactly